Inspection workspace

    Old House
    Inspection Guide

    Room-by-room and system-by-system inspection guidance for Canadian homes built 1900–1990.

    Early twentieth-century Canadian red-brick heritage house with a broad porch and mature trees
    Heritage home / observation before assessmentOldHouses.ca archive

    Stop condition. If you encounter exposed conductors, a fuel smell, or apparent structural movement, end the walkthrough and contact the utility, your provincial safety authority, or a licensed professional before going further.

    This page helps you record observations and decide who to ask; it does not assess a property. Do not disturb suspect materials or open electrical equipment. Health Canada advises having suspect materials assessed by a qualified person rather than judged by appearance.

    Where to investigate: a system map

    Eight areas worth covering in an older Canadian home, each with what you might observe, the question it raises, and who can answer it. Select a marker or a list item to read the entry.

    Illustrated cutaway drawing of a two-storey house showing the basement with furnace, water heater and drain piping, service entry and electrical panel, plumbing risers to an upstairs bathroom, insulated attic, chimney, porch, and buried drainage lines beside the foundation.
    Educational illustration. Original drawing commissioned for OldHouses.ca showing a generic older house in section. It is not a drawing of any real property and is never diagnostic evidence. Marker positions are indicative only.

    Areas to cover

    1. Site and drainage

    What you might observe
    Ground slope toward or away from the wall, downspout discharge points, window wells, and buried drainage lines.
    The question it raises
    Where does surface and roof water actually go, and has that changed since the house was built?
    Who can answer it
    Drainage or landscaping contractor; a plumber or drain contractor for buried lines.
    Foundations through time
    Inspection scope builder

    Build the scope before anyone attends

    Record what you want examined and, as you go, whether each item is still unchecked, only observed visually, or confirmed by a qualified professional or an authoritative record. Everything is entered by you and stays in your browser; nothing here diagnoses a property.

    0 confirmed · 0 observed only · 9 not checked yet · 0 not applicable

    Swipe sideways to compare columns

    Editable inspection scope with evidence state per item
    SystemWhat to examineEvidence stateWho can establish itNotesRemove

    Questions for the specialist

    • Which parts of this system did you actually see, and which were concealed?
    • Is what you are telling me an observation, or a conclusion you can put in writing?
    • What further testing or record would change your opinion?
    • Was this work done under permit, and can that be verified with the authority?
    • Which items are safety questions, and which are planning questions?
    • What should I ask my insurer or lender about before removing conditions?

    Documents and permits to request

    • Building, electrical, plumbing, gas and structural permits with final inspection dates
    • Service invoices for the heating appliance, water heater and any chimney work
    • Roof, window, foundation or waterproofing warranties and installer names
    • Any environmental testing reports (asbestos, lead, radon, oil tank, mould)
    • Previous inspection reports and any engineer's letters
    • Utility locate or oil-tank removal documentation where applicable
    • Insurance history questions: prior claims and any conditions imposed on coverage

    Permit records come from the municipality or the provincial authority — see the provincial source directory.

    Enhanced Pre-Inspection Checklist

    This comprehensive checklist addresses the unique characteristics of Canadian pre-1970 construction, including regional materials, climate considerations, and era-specific systems.

    Structural Elements

    • Foundation type (stone, brick, concrete block) and condition
    • Presence of weeping tile/perimeter drainage systems
    • Framing type (balloon vs platform) and fire safety implications
    • Sagging floors, bouncy areas, or uneven surfaces
    • Cracks in walls, especially around windows and doors
    • Roof line straightness and chimney condition
    • Load-bearing beam condition and unauthorized modifications

    Electrical Systems

    • Service capacity (60-amp often insufficient for modern needs)
    • Wiring type (knob-and-tube, aluminum, copper) and safety
    • Electrical panel condition, capacity, and breaker labeling
    • GFCI protection in bathrooms, kitchens, and outdoors
    • Outlet and switch functionality throughout house
    • Proper grounding and bonding systems
    • Evidence of DIY electrical work or code violations

    Plumbing Systems

    • Pipe materials and age (galvanized steel, cast iron, lead, copper)
    • Water pressure and flow in all fixtures
    • Water heater age, condition, venting, and efficiency
    • Drainage speed and any backup signs
    • Lead content testing in pipes and solder joints
    • Shut-off valve locations and functionality
    • Sewer line condition and potential tree root intrusion

    HVAC & Heating Systems

    • Heating system type and efficiency (octopus furnaces, boilers)
    • Ductwork condition, size adequacy, and insulation
    • Oil tank condition and insurance implications
    • Asbestos insulation around heating components
    • Chimney and flue condition for combustion appliances
    • Ventilation adequacy throughout the home
    • Carbon monoxide detector presence and functionality

    Building Envelope

    • Siding material and condition (wood, brick, asbestos-cement)
    • Roof condition and material (slate, asphalt, wood shingles)
    • Window type (single-pane) and thermal performance
    • Insulation presence, type, and R-value adequacy
    • Air sealing around penetrations and joints
    • Storm window condition and seasonal functionality
    • Weather stripping and caulking effectiveness

    Hazardous Materials Assessment

    • Asbestos in insulation, flooring, and textured ceilings
    • Lead paint on interior and exterior surfaces
    • Vermiculite insulation (potential asbestos contamination)
    • UFFI (Urea-Formaldehyde Foam Insulation) presence
    • Friable materials that may release harmful fibers
    • Professional testing requirements before renovation
    • Safe handling and disposal procedures

    Critical Safety Red Flags

    Stop and Call a Professional Immediately If You Find:

    • • Exposed knob-and-tube wiring or makeshift electrical connections
    • • Friable (crumbling) asbestos insulation or siding
    • • Major foundation cracks or structural sagging
    • • Gas leaks or improper gas line connections
    • • Extensive water damage or active leaks
    • • Strong musty odors indicating mold growth
    • • Electrical panels that feel warm or emit odors
    • • Aluminum wiring without proper connections
    • • Lead pipes in drinking water system
    • • Uneven floors suggesting structural failure
    • • Evidence of rodent or pest infestation
    • • Carbon monoxide detector alarms